Class 10a at least 1 accessible unisex sanitary facility at each bank of sanitary facilities for males and females.
Does an non accessible floor need accessible toilet.
Refer to figure a.
Where it is technically infeasible to alter existing toilet and bathing facilities to be accessible an accessible unisex toilet or bathing facility is permitted.
12 years ago thelunatick1.
Essentially wherever toilets are provided in buildings that are required to be accessible in most cases at least 1 accessible unisex sanitary facility must be provided.
The unisex facility shall be located on the same floor and in the same area as the existing facilities.
The door swing is allowed to overlap the clearance for a water closet and a lavatory in a toilet room as long as there is a 30 760 mm x 48 1220 mm clear floor space beyond the arc of the door.
The accessible urinal is required to have a 30 x 48 760 mm x 1220 mm clear floor or ground space positioned for forward approach.
Refer to figure e.
When it is technically infeasible to make existing men s and women s rooms comply an accessible unisex toilet room can be provided instead if it is in the same area and on the same floor as the existing toilet rooms 213 2 ex.
Where urinals are placed in a alcove deeper than 24 610 mm then the alcove must be 36 min 915 mm wide.
Where technical infeasibility is encountered compliance is still required to the maximum extent feasible.
Refer to figure b.